SFZ-344-Circuit-Breaker

SFZ-344 Circuit Breaker Helium Leak Detection System

A configurable vacuum chamber helium leak detection solution for circuit breakers and sealed electric-power components, designed around part size, SF6 or SF6-free gas filling pressure, target leak rate, cycle time, and helium recovery requirements.

I Main Technical Specs

Leak Rate Standard
3.0×10⁻⁸ Pa·m³/s (0.1%/year)
Chamber Quantity
1
Chamber Size
Shall be determined by customer products, for example 900 (W) × 600 (H) × 400 (D) mm
Number of Workpieces Tested per Chamber
1
Cycle Time
Shall be determined by the customer
Testing Parameters:
Helium Pressure
0.15-0.18 MPa, with adjustable pressure within this range
SF6 or SF6-free gas charging pressure (absolute pressure)
0-0.2 MPa, adjustable within this range
Leak Detector Start Testing Pressure
≤ 30 Pa inside the vacuum chamber
Workpiece Evacuation Pressure
≤ 2000 Pa, adjustable upward
Helium Recovery Rate
98%

II System Working Principle

SFZ-344 circuit breaker vacuum chamber helium leak detection system principle diagram
1

Gross Leak Detection Under Vacuum and Pressure Holding

Place the workpiece into the vacuum chamber and complete the connections. Press the Start button once. The vacuum chamber door will close automatically. Open V3 and close all other valves to pre-evacuate the vacuum chamber.

After the chamber reaches a certain vacuum level, the workpiece will undergo a pressure holding test for several seconds. If there is no large leak, the pressure will remain stable. The system will then continue evacuating both the vacuum chamber and the workpiece to the preset value.

If the pressure cannot be maintained within the specified time, it indicates a large leak in the workpiece. The system will automatically trigger an audible and visual alarm. At this point, stop the system, press the Reset button, open the chamber door, and remove the workpiece.

2

Micro Leak Detection

If no large leak is detected, the system will automatically open V4 to evacuate the workpiece. At this stage, both the vacuum chamber and the workpiece are evacuated simultaneously.

When the vacuum chamber pressure reaches 30 Pa and the workpiece pressure reaches 2000 Pa, the leak detector will start automatically to measure the helium background level inside the chamber and record the value.

During the leak test, the measured leak rate will be automatically compensated by subtracting the background value, ensuring that the displayed value represents the actual leak rate of the workpiece.

The system will then close V4 and open V5 to fill the workpiece with helium for fine leak testing. The system automatically determines whether the workpiece passes or fails and provides prompts or audible and visual alarms accordingly.

3

Helium Recovery

After the fine leak test is completed, the system automatically enters the helium recovery process.

4

SF6 Filling

After the helium inside the workpiece has been recovered, the vacuum chamber remains under vacuum. The system automatically opens the SF6 filling interface, and SF6 gas is charged into the workpiece.

Once the filling process is completed, open the chamber door, remove the workpiece, and the inspection process is finished.

III System Workflow

NG

OK

NG

OK

Manually load workpiece into chamber,
connect the connectors

Press start, chamber door close

Evacuate the chamber,
Detect the workpiece pressure

Gross leak check

Alarm, Vent workpiece,
door open

Take out NG workpiece

Evacuate workpiece

Chamber & workpiece vacuum level reach;
Workpiece He charging

Helium leak check

Alarm;
Helium recovery;
Door open

Take out NG workpiece

Helium recovery

Evacuate workpiece

SF6 charging

Door open, take out workpiece

IV Main Optional Configurations

Components Brand Options
Helium Leak Detector Wayeal / Inficon / Leybold
Vacuum Pump Leybold / Edwards / Atlas Copco
Compressor Ingersoll Rand / Desran
Solenoid Valve GSR / COAX / CKD / SMC
Vacuum Gauge Wayeal / Inficon / Leybold
Pressure Sensor Micro Sensor / Airtac / WIKA
Vacuum Valve Wayeal / CKD
Safety Light Curtain Lion / SENSORC
PLC (Programmable Logic Controller) Schneider / Siemens / Mitsubishi / Omron / Inovance
Touch Screen Panel Weinview / Schneider Electric
Handheld Barcode Scanner Honeywell / Keyence
Industrial PC Advantech
Printer TSC
Electrical Components Schneider / Panasonic / IDEC, etc.

Configure SFZ-344 For Your Circuit Breaker

Send us your circuit breaker dimensions, connector layout, target leak rate, helium pressure, SF6 or SF6-free gas filling pressure, cycle time, and automation needs. We will match the chamber, pump set, fixture, and helium recovery design to your process.