Skip to main content
Wayeal

Buying guides / Brand comparison

Helium Leak Detector Brand Comparison

Wayeal vs. INFICON, Leybold & Pfeiffer

This guide compares Wayeal SFJ-231 with best-selling models from INFICON, Leybold and Pfeiffer: UL1000, PHOENIX Quadro wet and ASM 340.

Wayeal SFJ-231 helium leak detector with backing pump and mobile cart
Wayeal SFJ-231Vacuum & sniffer leak detection

The Wayeal advantage

Sensitive detection. A practical working setup.

01

Core vacuum performance to match

All four models list a vacuum detection limit of 5 × 10⁻¹² mbar·L/s and a response time of <1 s. Wayeal meets the same listed core specifications for sensitive vacuum leak detection.

02

A high-capacity backing pump

The listed SFJ-231 configuration uses a Leybold D16C backing pump, with the highest pump-speed rating in this comparison at 50 Hz. Confirm the installed pump and validate evacuation time on your workpiece.¹

03

Quick startup. Clear operation.

Wayeal lists startup within two minutes, matching Leybold and below the listed figures for INFICON and Pfeiffer. Its 7-inch color touchscreen also offers a larger display than the UL1000’s listed 3.5-inch LCD.

04

More included in the configuration

RS232, RS485 and two USB ports support equipment communication and data workflows. The mobile cart is included, while it is listed as an extra-cost accessory for the Leybold and Pfeiffer configurations.²

Four models. One view.

Compare the specifications

Wayeal highlighted

Compare these specific models and listed configurations. Vacuum and sniffer limits are shown separately; pump ratings describe the backing pump, not measured test-cycle performance.

Scroll horizontally to see all four models →

Helium leak detector specification comparison
Specification WayealSFJ-231
Wayeal SFJ-231 helium leak detector with mobile cart
INFICONUL1000
INFICON UL1000 series leak detector, UL1000 fab configuration pictured
UL1000 fab pictured³
LeyboldPHOENIX Quadro wet
Leybold PHOENIX Quadro helium leak detector from the supplied comparison
PfeifferASM 340
Pfeiffer ASM 340 helium leak detector from the supplied comparison
Detection performance
Minimum detectable leak rate · vacuummbar·L/s · lower is more sensitive 5 × 10⁻¹²5 × 10⁻¹²5 × 10⁻¹²
Minimum detectable leak rate · sniffermbar·L/s · lower is more sensitive 5 × 10⁻⁸1 × 10⁻⁹5 × 10⁻⁸
Maximum inlet pressurePa 1,5001,5002,500
Response timeListed detector response <1 s<1 s<1 s
Startup timemin ≤3≤23
Backing pump · listed 50 Hz configuration¹
Backing-pump modelRotary vane Leybold D16BLeybold D2.5 EPfeiffer Pascal 1015 SD
Backing-pump pumping speed¹m³/h · 50 Hz · pump rating 16.52.514
Operation & included configuration²
Operator display 3.5-inch LCD7-inch touchscreen7-inch touchscreen
Communication interfaces RS232RS232, RS485, 2 × USBRS232, 2 × USB
Mobile cart² IncludedExtra-cost accessoryExtra-cost accessory
Dimensions · W × D × H²mm · listed configurations 1,068 × 525 × 850495 × 475 × 318547 × 375 × 389

How to read this comparison

1. Pump configuration: Figures are the listed backing-pump ratings at 50 Hz. They are distinct from helium pumping speed and complete-detector evacuation performance. Pump options and frequency affect the applicable rating.

2. Configuration scope: Cart inclusion and dimensions refer to the listed configurations. The dimensions may include different accessories; confirm the complete installed footprint and what is included in the quote.

3. Product images: Competitor photographs come from the supplied comparison. The INFICON photograph shows a UL1000 fab, while the comparison specifies UL1000. Images illustrate the product families; pictured configurations may differ from the quoted configuration.

Units: 1 mbar·L/s = 0.1 Pa·m³/s. The shared vacuum limit of 5 × 10⁻¹² mbar·L/s equals 5 × 10⁻¹³ Pa·m³/s.

Make your shortlist work harder

Put the SFJ-231 to the test on your application.

Share your workpiece, leak-rate limit, test method and target cycle time. Ask Wayeal for a configuration recommendation and a quotation matched to your process.

Discuss your application View SFJ-231 product details →

Questions buyers ask

Helium leak detector comparison FAQs

Does Wayeal SFJ-231 match INFICON UL1000, Leybold PHOENIX Quadro wet and Pfeiffer ASM 340 in vacuum sensitivity?

Yes. Wayeal SFJ-231, INFICON UL1000, Leybold PHOENIX Quadro wet and Pfeiffer ASM 340 all list a minimum detectable leak rate of 5 × 10⁻¹² mbar·L/s in vacuum mode. This is equivalent to 5 × 10⁻¹³ Pa·m³/s. It is a detector specification; the achievable result on your part also depends on the fixture, vacuum background and test method.

Why consider the Wayeal SFJ-231?

The SFJ-231 combines the same listed vacuum sensitivity and sub-second detector response as the compared models with a high-capacity backing pump, startup within two minutes, a 7-inch touchscreen, RS232 and RS485 communication, two USB ports and an included mobile cart. Evaluate the complete configuration against your production requirements.

Plan Your Helium Leak Testing Project

Share your part size, material, target leak rate, cycle time, and production workflow. Wayeal will recommend a professional helium leak detection configuration for your application.